{"id":670,"date":"2018-03-05T04:52:17","date_gmt":"2018-03-05T04:52:17","guid":{"rendered":"https:\/\/www.plc-control.net\/?page_id=670"},"modified":"2018-03-19T06:48:48","modified_gmt":"2018-03-19T06:48:48","slug":"utb-u11-problemy-a-veci-k-doreseni","status":"publish","type":"page","link":"https:\/\/www.plc-control.net\/en\/utb-u11-problemy-a-veci-k-doreseni\/","title":{"rendered":"UTB \/ U11 \/ Probl\u00e9my a v\u011bci k do\u0159e\u0161en\u00ed"},"content":{"rendered":"<ul>\n<li><span style=\"color: #008000;\"><strong>03.03.2018 VY\u0158E\u0160ENO<\/strong><\/span>\n<ul>\n<li><span style=\"color: #000000;\">VZT 4<\/span>\n<ul>\n<li>Tlak na p\u0159\u00edvodu a odtahu VZT jednotky se zobrazuje v kPa s jedn\u00edm desetinn\u00fdm m\u00edstem\n<ul>\n<li>V podkladech pro BMS je po\u017eadavek na Pa bez \u017e\u00e1dn\u00e9ho desetinn\u00e9ho m\u00edsta<\/li>\n<li>06.03.2018 opraveno<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li><span style=\"color: #008000;\"><strong>03.03.2018 VY\u0158E\u0160ENO<\/strong><\/span>\n<ul>\n<li><span style=\"color: #000000;\">VZT 4<\/span>\n<ul>\n<li>\u010cist\u00e9 prostory\n<ul>\n<li>P\u0159etlak se zobrazuje v kPa\n<ul>\n<li>V podkladech pro BMS je po\u017eadavek na Pa<\/li>\n<li>06.03.2018 opraveno<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li><span style=\"color: #ff0000;\"><strong>03.03.2018 NEVY\u0158E\u0160ENO<\/strong><\/span>\n<ul>\n<li>VZT 4\n<ul>\n<li>EPS\n<ul>\n<li>V BMS se nezobrazuj\u00ed data z \u010didel<\/li>\n<li>09.03.2018 &#8211; \u010dek\u00e1 se na to, a\u017e se poda\u0159\u00ed p\u0159ipojit na OPC server a namapovat p\u0159\u00edslu\u0161n\u00e9 datov\u00e9 body ze strany firmy TechniServ. Bude urgov\u00e1no.<\/li>\n<li>18.03.2018 &#8211; pan \u0160ulc sd\u011blil, \u017ee se postar\u00e1 o vy\u0159e\u0161en\u00ed tohoto probl\u00e9mu<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li><span style=\"color: #ff0000;\"><strong>03.03.2018 NEVY\u0158E\u0160ENO<\/strong><\/span>\n<ul>\n<li><span style=\"color: #000000;\">VZT 4<\/span>\n<ul>\n<li>EZS\n<ul>\n<li>V BMS se nezobrazuj\u00ed data z \u010didel<\/li>\n<li>09.03.2018 &#8211; Do BMS zapracov\u00e1no, ale nep\u0159ehr\u00e1no na ostr\u00fd server<\/li>\n<li>12.03.2018 &#8211; \u010didla zakreslena, ale nebyla upraven\u00e1 stavebn\u00ed dispozice<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li><span style=\"color: #008000;\"><strong>03.03.2018 VY\u0158E\u0160ENO<\/strong><\/span>\n<ul>\n<li>VZT 4\n<ul>\n<li>Trendy\n<ul>\n<li>P\u0159i kontrole zobrazen\u00ed se nena\u010d\u00edt\u00e1 \u010dte\u010dka trend\u016f a nen\u00ed mo\u017eno zobrazit historick\u00e1 data.<\/li>\n<li>06.03.2018 &#8211; vy\u0159e\u0161eno<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li><span style=\"color: #008000;\"><strong>08.03.2018 VY\u0158E\u0160ENO<\/strong><\/span>\n<ul>\n<li>VZT 4\n<ul>\n<li>Do p\u0159\u00edslu\u0161n\u00e9ho registru se pomoc\u00ed BMS nezapisuje venkovn\u00ed teplota objektu U11<\/li>\n<li>12.03.2018 &#8211; po\u017e\u00e1d\u00e1no o n\u00e1pravu u firmy TechniServ<\/li>\n<li>12.03.2018 &#8211; firmou TechniServ vy\u0159e\u0161eno<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li><span style=\"color: #ff0000;\"><strong>08.03.2018 VY\u0158E\u0160ENO<\/strong><\/span>\n<ul>\n<li><span style=\"color: #000000;\">VZt 4<\/span>\n<ul>\n<li>Zji\u0161t\u011bno, \u017ee se Porucha p\u0159etlaku v \u010dist\u00fdch prostorech zobrazuje inverzn\u011b v BMS. Re\u00e1ln\u011b porucha v \u010dist\u00e9m prostoru nen\u00ed, ale v BMS se zobrazuje, \u017ee ano.<\/li>\n<li>Zasl\u00e1na prosba na TechniServ,aby bylo opraveno.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li><span style=\"color: #ff0000;\"><strong>19.03.2018 VY\u0158E\u0160ENO<\/strong><\/span>\n<ul>\n<li><span style=\"color: #000000;\">VZT 4\u00a0<\/span>\n<ul>\n<li>Zji\u0161t\u011bno, \u017ee v p\u0159es BMS nejde nastavit tlak pro p\u0159\u00edvod a odtah v pln\u00e9m re\u017eimu<\/li>\n<li>Bude zasl\u00e1na prosba na TechniServ, aby bylo opraveno.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li><span style=\"color: #ff0000;\"><strong>19.03.2018 VY\u0158E\u0160ENO<\/strong><\/span>\n<ul>\n<li>VZT4\n<ul>\n<li>Zji\u0161t\u011bno, \u017ee v BMS se nekorektn\u011b zobrazuje alarm pro \u010dist\u00fd prostor A a D<\/li>\n<li>Bude zasl\u00e1na prosba na TechniServ, aby bylo\u00a0zji\u0161t\u011bno pro\u010d<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li><span style=\"color: #ff0000;\"><strong>19.03.2018 VY\u0158E\u0160ENO<\/strong><\/span>\n<ul>\n<li>VZT4\n<ul>\n<li>Bylo zji\u0161t\u011bno, \u017ee v BMS nejde korektn\u011b nastavit hodnota hystereze u \u010dist\u00fdch prostor p\u0159i vyhodnocov\u00e1n\u00ed alarmu<\/li>\n<li>Bude zasl\u00e1na prosba na TechniServ, aby bylo\u00a0zji\u0161t\u011bno pro\u010d<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li><span style=\"color: #ff0000;\"><strong>19.03.2018 VY\u0158E\u0160ENO<\/strong><\/span>\n<ul>\n<li><span style=\"color: #000000;\">VZT4<\/span>\n<ul>\n<li>Bylo zji\u0161t\u011bno, \u017ee v BMS\u00a0jde sice nastavit hodnota tlaku na p\u0159\u00edvodu v tlumen\u00e9m re\u017eimu, ale zp\u011btn\u011b se zobraz\u00ed p\u016fvodn\u00ed hodnota.<\/li>\n<li>Bude zasl\u00e1na prosba na TechniServ, aby bylo\u00a0zji\u0161t\u011bno pro\u010d<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li><span style=\"color: #ff0000;\"><strong>19.03.2018 VY\u0158E\u0160ENO<\/strong><\/span>\n<ul>\n<li>VZT4\n<ul>\n<li>Bylo zji\u0161t\u011bno, \u017ee se nezobrazuje aktu\u00e1ln\u00ed p\u0159etlak v prostoru MC118. Zobrazuje se st\u00e1le hodnota 42.2Pa, ale re\u00e1ln\u00e1 je aktu\u00e1ln\u011b 20 Pa. Zd\u00e1 se, jakoby cel\u00e1 komunikace byla zaseknut\u00e1.<\/li>\n<li>Bude zasl\u00e1na prosba na TechniServ, aby bylo\u00a0zji\u0161t\u011bno pro\u010d.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>03.03.2018 VY\u0158E\u0160ENO VZT 4 Tlak na p\u0159\u00edvodu a odtahu VZT jednotky se zobrazuje v kPa s jedn\u00edm desetinn\u00fdm m\u00edstem V podkladech pro BMS je po\u017eadavek na Pa bez \u017e\u00e1dn\u00e9ho desetinn\u00e9ho m\u00edsta 06.03.2018 opraveno 03.03.2018 VY\u0158E\u0160ENO VZT 4 \u010cist\u00e9 prostory P\u0159etlak se zobrazuje v kPa V podkladech pro BMS je po\u017eadavek na Pa 06.03.2018 opraveno 03.03.2018 [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-670","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>UTB \/ U11 \/ Probl\u00e9my a v\u011bci k do\u0159e\u0161en\u00ed - PLC &amp; HMI Programov\u00e1n\u00ed<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.plc-control.net\/en\/utb-u11-problemy-a-veci-k-doreseni\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"UTB \/ U11 \/ Probl\u00e9my a v\u011bci k do\u0159e\u0161en\u00ed - PLC &amp; HMI Programov\u00e1n\u00ed\" \/>\n<meta property=\"og:description\" content=\"03.03.2018 VY\u0158E\u0160ENO VZT 4 Tlak na p\u0159\u00edvodu a odtahu VZT jednotky se zobrazuje v kPa s jedn\u00edm desetinn\u00fdm m\u00edstem V podkladech pro BMS je po\u017eadavek na Pa bez \u017e\u00e1dn\u00e9ho desetinn\u00e9ho m\u00edsta 06.03.2018 opraveno 03.03.2018 VY\u0158E\u0160ENO VZT 4 \u010cist\u00e9 prostory P\u0159etlak se zobrazuje v kPa V podkladech pro BMS je po\u017eadavek na Pa 06.03.2018 opraveno 03.03.2018 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.plc-control.net\/en\/utb-u11-problemy-a-veci-k-doreseni\/\" \/>\n<meta property=\"og:site_name\" content=\"PLC &amp; HMI Programov\u00e1n\u00ed\" \/>\n<meta property=\"article:modified_time\" content=\"2018-03-19T06:48:48+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.plc-control.net\/utb-u11-problemy-a-veci-k-doreseni\/\",\"url\":\"https:\/\/www.plc-control.net\/utb-u11-problemy-a-veci-k-doreseni\/\",\"name\":\"UTB \/ U11 \/ Probl\u00e9my a v\u011bci k do\u0159e\u0161en\u00ed - PLC &amp; HMI Programov\u00e1n\u00ed\",\"isPartOf\":{\"@id\":\"https:\/\/www.plc-control.net\/#website\"},\"datePublished\":\"2018-03-05T04:52:17+00:00\",\"dateModified\":\"2018-03-19T06:48:48+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.plc-control.net\/utb-u11-problemy-a-veci-k-doreseni\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.plc-control.net\/utb-u11-problemy-a-veci-k-doreseni\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.plc-control.net\/utb-u11-problemy-a-veci-k-doreseni\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Dom\u016f\",\"item\":\"https:\/\/www.plc-control.net\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"UTB \/ U11 \/ Probl\u00e9my a v\u011bci k do\u0159e\u0161en\u00ed\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.plc-control.net\/#website\",\"url\":\"https:\/\/www.plc-control.net\/\",\"name\":\"PLC &amp; HMI Programov\u00e1n\u00ed\",\"description\":\"Allen-Bradley, Beckhoff, Click-KOYO, Fatek, IDEC, Mitsubishi, SAIA, Siemens, Tecomat, Unitronics, Weintek\",\"publisher\":{\"@id\":\"https:\/\/www.plc-control.net\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.plc-control.net\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.plc-control.net\/#organization\",\"name\":\"Programov\u00e1n\u00ed PLC\",\"url\":\"https:\/\/www.plc-control.net\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/www.plc-control.net\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.plc-control.net\/wp-content\/uploads\/2016\/08\/favicon.png\",\"contentUrl\":\"https:\/\/www.plc-control.net\/wp-content\/uploads\/2016\/08\/favicon.png\",\"width\":76,\"height\":76,\"caption\":\"Programov\u00e1n\u00ed PLC\"},\"image\":{\"@id\":\"https:\/\/www.plc-control.net\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"UTB \/ U11 \/ Probl\u00e9my a v\u011bci k do\u0159e\u0161en\u00ed - PLC &amp; HMI Programov\u00e1n\u00ed","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.plc-control.net\/en\/utb-u11-problemy-a-veci-k-doreseni\/","og_locale":"en_GB","og_type":"article","og_title":"UTB \/ U11 \/ Probl\u00e9my a v\u011bci k do\u0159e\u0161en\u00ed - PLC &amp; HMI Programov\u00e1n\u00ed","og_description":"03.03.2018 VY\u0158E\u0160ENO VZT 4 Tlak na p\u0159\u00edvodu a odtahu VZT jednotky se zobrazuje v kPa s jedn\u00edm desetinn\u00fdm m\u00edstem V podkladech pro BMS je po\u017eadavek na Pa bez \u017e\u00e1dn\u00e9ho desetinn\u00e9ho m\u00edsta 06.03.2018 opraveno 03.03.2018 VY\u0158E\u0160ENO VZT 4 \u010cist\u00e9 prostory P\u0159etlak se zobrazuje v kPa V podkladech pro BMS je po\u017eadavek na Pa 06.03.2018 opraveno 03.03.2018 [&hellip;]","og_url":"https:\/\/www.plc-control.net\/en\/utb-u11-problemy-a-veci-k-doreseni\/","og_site_name":"PLC &amp; HMI Programov\u00e1n\u00ed","article_modified_time":"2018-03-19T06:48:48+00:00","twitter_card":"summary_large_image","twitter_misc":{"Estimated reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.plc-control.net\/utb-u11-problemy-a-veci-k-doreseni\/","url":"https:\/\/www.plc-control.net\/utb-u11-problemy-a-veci-k-doreseni\/","name":"UTB \/ U11 \/ Probl\u00e9my a v\u011bci k do\u0159e\u0161en\u00ed - PLC &amp; HMI Programov\u00e1n\u00ed","isPartOf":{"@id":"https:\/\/www.plc-control.net\/#website"},"datePublished":"2018-03-05T04:52:17+00:00","dateModified":"2018-03-19T06:48:48+00:00","breadcrumb":{"@id":"https:\/\/www.plc-control.net\/utb-u11-problemy-a-veci-k-doreseni\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.plc-control.net\/utb-u11-problemy-a-veci-k-doreseni\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.plc-control.net\/utb-u11-problemy-a-veci-k-doreseni\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Dom\u016f","item":"https:\/\/www.plc-control.net\/"},{"@type":"ListItem","position":2,"name":"UTB \/ U11 \/ Probl\u00e9my a v\u011bci k do\u0159e\u0161en\u00ed"}]},{"@type":"WebSite","@id":"https:\/\/www.plc-control.net\/#website","url":"https:\/\/www.plc-control.net\/","name":"PLC &amp; HMI Programov\u00e1n\u00ed","description":"Allen-Bradley, Beckhoff, Click-KOYO, Fatek, IDEC, Mitsubishi, SAIA, Siemens, Tecomat, Unitronics, Weintek","publisher":{"@id":"https:\/\/www.plc-control.net\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.plc-control.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/www.plc-control.net\/#organization","name":"Programov\u00e1n\u00ed PLC","url":"https:\/\/www.plc-control.net\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.plc-control.net\/#\/schema\/logo\/image\/","url":"https:\/\/www.plc-control.net\/wp-content\/uploads\/2016\/08\/favicon.png","contentUrl":"https:\/\/www.plc-control.net\/wp-content\/uploads\/2016\/08\/favicon.png","width":76,"height":76,"caption":"Programov\u00e1n\u00ed PLC"},"image":{"@id":"https:\/\/www.plc-control.net\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.plc-control.net\/en\/wp-json\/wp\/v2\/pages\/670","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.plc-control.net\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.plc-control.net\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.plc-control.net\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.plc-control.net\/en\/wp-json\/wp\/v2\/comments?post=670"}],"version-history":[{"count":12,"href":"https:\/\/www.plc-control.net\/en\/wp-json\/wp\/v2\/pages\/670\/revisions"}],"predecessor-version":[{"id":739,"href":"https:\/\/www.plc-control.net\/en\/wp-json\/wp\/v2\/pages\/670\/revisions\/739"}],"wp:attachment":[{"href":"https:\/\/www.plc-control.net\/en\/wp-json\/wp\/v2\/media?parent=670"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}